List of "hw_type" for Home + Control API
Hi All!
Self is working on Integration of Legrand devices with Home+Control API to Automation Processor. Further, to precisely understand the device type (hw_type) from the reply received for ‘Get Plant’s Topology’. I would request for the list of “hw_type”s like
NLL = Light (Switchable),
NLF = Light (Dimmable),
NLLV=Rolling Shutter, etc.
Looking forward for valuable reply.
Regards,
Anil K Chikkam.
Hello Anil,
Here is the list (soon available in the “Documentation” part) :
- NLC – Cable Outlet
- NLF – On-Off dimmer switch
- NLP – Socket Outlet
- NLPM – Mobile Socket Outlet
- NLP – Din
- NLM – Micromodule
- NLV – Shutter switch
- NLLV – Shutter switch w. level
- NLL – On-Off toggle switch
- NLD – Double OnOff dim. remote
- NLT – On-Off dimmer remote / UpDown remote / HomeAway remote / WakeupSleep remote / OnOff Toggle remote
Have a good day,
Leslie – Community Manager
What’s the difference between:
<ul style=”box-sizing: inherit; margin: 0px 0px 1rem 1.25rem; padding: 0px; list-style-position: outside; line-height: 1.6; color: #000000; font-family: ‘Segoe UI’, ‘Noto Sans’, sans-serif;”>
<li style=”box-sizing: inherit; margin: 0px; padding: 0px; font-size: inherit;”>NLV – Shutter switch
<li style=”box-sizing: inherit; margin: 0px; padding: 0px; font-size: inherit;”>NLLV – Shutter switch w. level
I can’t find the “<span style=”color: #000000; font-family: ‘Segoe UI’, ‘Noto Sans’, sans-serif;”>Shutter switch w. level</span>” product in the Legrand website.
It is just a fw update from the NLV?
Hello JD,
NLLV is our new generation of roller shutters switches with level detection
References for NLV :
Legrand ref | Bticino ref |
LG-067726 LG-067776 LG-064896 LG-077706L LG-600086 LG-600186 LG-752190 LG-752290 LG-752390 LG-752590 LG-752690 LG-752790 LG-752890 LG-752990 LG-741807 LG-741837 LG-741867 LG-100064 LG-100084 |
BT-K4027CM2 BT-N4027CM2 BT-NT4027CM2 BT-L4027CM2 BT-RW4027CM2 BT-RG4027CM2 BT-RA4027CM2 |
References for NLLV :
Legrand ref | Bticino ref |
LG-574204 LG-574213 LG-574222 LG-574231 |
BT-K4027C BT-RW4027C BT-RG4027C BT-RA4027C BT-N4027C BT-NT4027C BT-L4027C |
Have a good day,
Leslie – Community Manager
Hi Sandro,
NLPS = Smart shedder for Connected cabinet :
proactively prevents electrical shutdowns in the home due to overloads. Intelligently shuts down relevant Legrand connected devices (contactor, power outlet, cable outlet from “with Netatmo” ranges) when consumption reaches a user-defined threshold
Have a good day,
Leslie – Community Manager
It’s not yet ready, but it will be implemented (in the next few months, I don’t have a more precise date for the moment)
I assume it answers also your other topic’s question 😉
Have a good day,
Leslie – Community Manager
Hi, Very interested in this list! It seems it’s not complete yet. I get a type NBR
. Any idea how I should name that?
Cheers
Hello Cyril,
Yes, the reference is 067726A (beware, to take the reference with the “A”, otherwise it’s the first generation of shutters)
Have a good day,
Leslie – Community Manager
Oh thank you !!!
With this reference we can :
- Set a specific position for the shutter like open at 10% ?
- Get feedback of current position like 10% (note only 0,50 & 100%) ?
- Control the LED state ?
Dis you know about zigbee2mqtt ? is it integrate ?
Hi again Cyril,
- Set a specific position for the shutter like open at 10% ? <= yes
- Get feedback of current position like 10% (note only 0,50 & 100%) ? <= yes
- Control the LED state ? <= good question. If it was possible with the 1st generation I don’t see why it would not be the case with this one. But I haven’t tested it, so I can’t tell
Dis you know about zigbee2mqtt ? is it integrate ? <= as all devices from the ranges Wiring devices … with Netatmo the switch is ZigBee 3.0 compatible. So, he can be integrated to a ZigBee compatible third-party hub
Have a good day,
Leslie – Community Manager
You must be logged in to reply to this topic.