How to change Zigbee channel for ZLSH06

Hi there,

I’ve got some Roller Shutter Switches (ZLSH06). I want to confirm whether they can work with a 3rd party Zigbee network and also how to change their Zigbee channel if possible. Home Assistant with ZHA by default uses 15.

Regards

Giorgos

Hello Giorgos,

Your switch will be able to be put in a ZigBee network

Here is the process to change channel :

  • Wired switch : it’s the procedure from this screenshot (I just have it in french)
  • Wireless switch with battery : when you reset the device, it will scan the 16 possible channels (feature available starting NLT-50 firmware). If a network is opened – and if your gateway accepts it -, your device will log on it. If several channels are opened, it could be difficult to detect the correct one. The best is (if possible) not to open several networks, or to use a software with a programing console to choose a specific channel
  • Wireless and batteryless switch : you have to do the manipulation from the notice as many times as necessary to scan all channels

 

Have a good day,

Leslie – Community Manager