wireless firmware 39
Hi Leslie,
I see firmware 39 is out for the wireless dimmer (WNRL63). Are you able to provide a change log?
Is there a better way for me to ask for this info, or ideally a way for me to look it up myself so I don’t have to bother you?
Thanks!
Hello Steven,
We only have an internal file for changelogs, so better is to ask me. I added in attachment a screenshot
Have a good day,
Leslie – Community Manager
Leslie,
I see OTA on zigbee 3.0 networks listed. Does this mean that we’re going to see the firmware made available for download so that OTA can happen on a non-Legrand zigbee gateway?
Hello Steven,
The firmware are available for the download since a few time : you can access firmware download page by following steps here : https://developer.legrand.com/local-interoperability/#ZigBee%20OTA
Update are a manual process, there is no automatic OTA update as we have with the Legrand gateway
Have a good day,
Leslie – Community Manager
Hello Steven,
The firmware are available for the download since a few time : you can access firmware download page by following steps here : https://developer.legrand.com/local-interoperability/#ZigBee%20OTA
Update are a manual process, there is no automatic OTA update as we have with the Legrand gateway
Have a good day,
Leslie – Community Manager
Thank you Leslie!
How do I translate my device model number into the correct NL* Cloud Type? For example, I think that the Wireless/Remote Dimmer (WNRL63) is an NLT, but the netatmo api site says it’s an NLDD, and the changelog you posted above is for an NLD. I also have other devices such as a wired dimmers, and outlets; is there a chart or cross-reference somewhere?
Hello Steven,
Your WNRL63 dimmer is a NLDD which is the Cloud Type we use for US versions. But it works with the “normal” NLD firmware
If you make a /homesdata call on your install you should retrieve the correct types : https://dev.netatmo.com/apidocumentation/control#homesdata
It’s complicated for me to provide a list of every Cloud Type for US references, the information about it is a bit spread everywhere in our documentation. In a nutshell : in main cases NLTx works with NLT firmware, NLDx with NLD firmware and so on
Hoping it helps,
Have a good day,
Leslie – Community Manager